    Hi everyone… I recently finished the Boogie 57 and on the test rig it works great. When I connect the jacks, foot switch, all I get is an oscillating  rumble when foot switch is engaged. with foot switch disengaged, it passes clean guitar sound.

     

    I look forward to learning what my mistake is.

     

    #32345
    Barry
    Keymaster

    Perhaps loose jfets when moving things around?

    The jack wiring looks correct.

    #32348
    Thomas a Meacham
    Participant

    Thanks for the quick reply Barry, I will check them.. also, if you noticed the 10004 diode, I burnt one of the solder pads and relocated what I think is the correct alternative (it works ) do you see any problem?

    #32359
    Thomas a Meacham
    Participant

    problem solved… used my audio probe and found several marginal solder joints. reflowed and works as it should.